Small size, lightweight
High vacuum level type and large vacuum flow type are optional
The generator has a vacuum breaking function itself
A separate vacuum filter and mounting bracket are optional
AZR 07 H - J - V - F
① ② ③ ④ ⑤ ⑥
① Series | ② Nozzle Diameter | ③ Specification | ④ Exhaust way | ⑤ Special specification | ⑥ Vacuum filter |
AZR | 05 - φ0.5mm | H - High vacuum level type | Nil - Direct exhaust | Nil - Standard type | Nil - Standard type |
07 - φ0.7mm | L - Large vacuum follow type | J - Centralized exhaust | V - Vacuum detecting port | F - With a vacuum filter |
Technical parameters
Model | Rated air supply pressure bar | Max. vacuum level -kPa | Max. vacuum flow NL/min | Air consumption NL/min | Noise level dB(A) | Weight g | Air supply port P | Recommended hose dia.(mm) Vacuum port |
AZR05H | 5 | 88 | 7 | 11 | 80 | 19 | φ4 | φ4 |
AZR07H | 5 | 88 | 12.5 | 22 | 80 | 20 | φ6 | φ6 |
AZR05L | 5 | 58 | 12 | 11 | 70 | 19 | φ4 | φ4 |
AZR07L | 5 | 58 | 20 | 22 | 70 | 20 | φ6 | φ6 |
Vacuum flow(NL/min) at different vacuum levels(-kPa)
Model | Air supply pressure bar | Air consumption NL/min | 0 | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | Max. vacuum level -kPa |
AZR05H | 5 | 11 | 8 | 7.3 | 6.3 | 5.2 | 4.2 | 3.4 | 2.2 | 1.4 | 1 | 88 |
AZR07H | 5 | 22 | 12.5 | 11.5 | 9.7 | 7.4 | 6.5 | 5.2 | 4.1 | 3 | 1.7 | 88 |
AZR05L | 5 | 11 | 12.5 | 10.5 | 8.7 | 6.9 | 5 | 2.9 | 1 | - | - | 58 |
AZR07L | 5 | 22 | 22 | 19.1 | 14.5 | 9.4 | 7.2 | 4.3 | 1 | - | - | 58 |
Evacuation time(s/L) to reach different vacuum levels(-kPa)
Model | Air supply pressure bar | Air consumption NL/min | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | Max. vacuum level -kPa |
AZRO5H | 5 | 11 | 0.42 | 0.83 | 1.3 | 1.92 | 3.2 | 4.5 | 6.3 | 10.5 | 88 |
AZRO7H | 5 | 22 | 0.34 | 0.75 | 7.22 | 1.87 | 2.7 | 3.8 | 5.7 | 9.9 | 88 |
AZRO5L | 5 | 17 | 0.32 | 0.64 | 7.06 | 1.73 | 2.9 | 8.2 | 58 | ||
AZRO7L | 5 | 22 | 0.23 | 0.53 | 0.93 | 7.53 | 2.8 | 7.8 | 58 |
Vacuum release principle and attention:
1. Close solenoid valve and stop air supply, open the release valve. The residual positive pressure air in the air circuit between check valve and release port flows into the vacuum circuit to release vacuum.
2 Change the tube length between the check valve and release port to adjust the residual positive pressure air volume. In this way, the vacuum releasing time can be adjusted
3. The vacuum releasing flow of this way is small
Vacuum release principle and attention:
1. Close the solenoid valve and stop air supply, open the release valve, and the positive pressure air flows directly into the vacuum circuit to release the vacuum
2. Can adjust the vacuum releasing time through controlling the air supply time of solenoid valve
3. Adjust the air releasing pressure through the reducing valve to avoid excessive pressure blowing away the workpiece
4. The air releasing pressure must be lower than air supply pressure of vacuum generator
5. The releasing flow and pressure can be adjusted freely as required